Japan-Top runner-Central HVAC - 2004
In 2007 the targets for 2004 were completed with those for air conditioners with a cooling capacity of over 4.0 kW, ducted type and Multi-type operating indoor units individually.
Targets:
Non-ducted wall-mounted type (except multi-type operating indoor units individually)
- Cooling capacity (CC) Up to 2.5kW - Standard energy consumption efficiency (COP) 5.27
- CC Over 2.5kW up to 3.2kW - COP 4.90
- CC Over 3.2kW up to 4.0kW - COP 3.65
- CC Over 4.0kW up to 7.1kW - COP 3.17
- CC Over 7.1kW up to 28.0kW - COP 3.10
Other non-ducted type (except multi-type operating indoor units individually)
- CC Up to 2.5kW - COP 3.96
- CC Over 2.5kW up to 3.2kW - COP 3.96
- CC Over 3.2kW up to 4.0kW - COP 3.20
- CC Over 4.0kW up to 7.1kW - COP 3.12
- CC Over 7.1kW up to 28.0kW - COP 3.06
Ducted type (except multi-type operating indoor units individually)
- CC Up to 4.0kW - COP 3.02
- CC Over 4.0kW up to 7.1kW - COP 3.02
- CC Over 7.1kW up to 28.0kW - COP 3.02
Multi-type operating indoor units individually
- CC Up to 4.0kW - COP 4.12
- CC Over 4.0kW up to 7.1kW - COP 3.23
- CC Over 7.1kW up to 28.0kW - COP 3.07