Japan-Top runner-Central HVAC - 2004

Last updated: 5 November 2017

In 2007 the targets for 2004 were completed with those for air conditioners with a cooling capacity of over 4.0 kW, ducted type and Multi-type operating indoor units individually.

 

Targets:

Non-ducted wall-mounted type (except multi-type operating indoor units individually)

  • Cooling capacity (CC) Up to 2.5kW - Standard energy consumption efficiency (COP) 5.27
  • CC Over 2.5kW up to 3.2kW - COP 4.90
  • CC Over 3.2kW up to 4.0kW - COP 3.65
  • CC Over 4.0kW up to 7.1kW - COP 3.17
  • CC Over 7.1kW up to 28.0kW - COP 3.10

Other non-ducted type (except multi-type operating indoor units individually)

  • CC Up to 2.5kW - COP 3.96
  • CC Over 2.5kW up to 3.2kW - COP 3.96
  • CC Over 3.2kW up to 4.0kW - COP 3.20
  • CC Over 4.0kW up to 7.1kW - COP 3.12
  • CC Over 7.1kW up to 28.0kW - COP 3.06

Ducted type (except multi-type operating indoor units individually)

  • CC Up to 4.0kW - COP 3.02
  • CC Over 4.0kW up to 7.1kW - COP 3.02
  • CC Over 7.1kW up to 28.0kW - COP 3.02

Multi-type operating indoor units individually

  • CC Up to 4.0kW - COP 4.12
  • CC Over 4.0kW up to 7.1kW - COP 3.23
  • CC Over 7.1kW up to 28.0kW - COP 3.07