TurkeyNational

Bep-TR (Regulation of energy performance of buildings) 2010

Applicable Building Type(s)

New non-residential, New residential

Policy Requirement Level

Mandatory

Policy Sequence

Governance

Development Authority: Ministry of Environment and Urbanism

Implementation Authority: Central internet based software system for all cities

Verification Authority: Local authorities

Enforcement Authority: Local authorities

Prescriptive Compliance path

Energy Requirements:

Insulation

TS 825 (similar to EN 13790) 

Climate

Wall

(W/m2K)

Roof

(W/m2K)

Floor

(W/m2K)

1 0.7 0.45 0.7
2 0.6 0.4 0.6
3 0.5 0.3 0.45
4 0.4 0.25 0.4

source: http://www.ecofys.com/files/files/ecofys-2016-u-value-maps-turkey.pdf

Windows

TS 825 

Climate

Windows

(W/m2K)

1 2.4
2 2.4
3 2.4
4 2.4

source: http://www.ecofys.com/files/files/ecofys-2016-u-value-maps-turkey.pdf

Air Leakage

TS EN 12207, TS EN 13465 

Water Heating System

EN 15316

Lighting

EN 15251, EN 12464, EN 12665, EN 13032 

Compliance Softwares:

Under development by the ministry

End-uses considered:

Space cooling, Space heating, Water heating

Performance Compliance path

Energy Requirements:

Resources

Notes

Climate zones