RussiaNational

Thermal Performance of Buildings (2003)

Applicable Building Type(s)

New residential

Policy Requirement Level

Mandatory

Policy Sequence

Governance

Development Authority: Ministry of regional development

Prescriptive Compliance path

Energy Requirements:

Insulation

Single-family

 
R-Values (m2.K/W)DoorRoofSuspended floorWalls
Climate zone I 0.3 2.8 3.2 2.1
Climate zone II 0.45 3.7 4.2 2.8
Climate zone III 0.6 4.6 5.2 3.5
Climate zone IV 0.7 5.5 6.2 4.2
Climate zone V 0.75 6.4 7.2 4.9
Climate zone VI 0.8 7.3 8.2 5.6

Windows

R-Values (m2.K/W)Multi-familySingle-family
Climate zone I 0.3 0.3
Climate zone II 0.45 0.45
Climate zone III 0.6 0.6
Climate zone IV 0.7 0.7
Climate zone V 0.75 0.75
Climate zone VI 0.8 0.8

Space Heating System

Single-family

Performance Compliance path

Energy Requirements:

Resources

Notes

Climate zones

CDD:

Cooling Degree Days

 

HDD:

Heating Degree Days

 

 
 CDDHDD
Climate zone I Not available 2000
Climate zone II Not available 4000
Climate zone III Not available 6000
Climate zone IV Not available 8000
Climate zone V Not available 10000
Climate zone VI Not available 12000