GreeceNational

EPBD Energy Performance Certificate (2010)

Scale relative to modelled consumption values. E.A. is total primary energy consumption of existing building, K.A. is the reference building

Class

A

0.33K.A < E.A. ≤ 0.50K.A.

A+

E.A. ≤ 0.33K.A

B

0.75K.A < E.A. ≤ 1.00K.A.

B+

0.50K.A < E.A. ≤ 0.75K.A.

E

1.82K.A < E.A. ≤ 2.27K.A.

H

2.73K.A.< E.A

Γ

1.00K.A < E.A. ≤ 1.41K.A.

Δ

1.41K.A < E.A. ≤ 1.82K.A.

Ζ

2.27K.A < E.A. ≤ 2.73K.A.

 

Applicable Building Type(s)

Existing non-residential, Existing residential

Policy Requirement Level

Mandatory

Policy Sequence

Governance

Development Authority: Ministry of Environment, Energy and Climate Change

Implementation Authority: Private Auditors

Verification Authority: MEECC (Hellenic Energy Inspectorate)

Enforcement Authority: MEECC (Hellenic Energy Inspectorate)

Compliance path

Energy Requirements:

End-uses considered:

Space cooling, Space heating, Water heating

Resources

Description

Notes

Climate Zones