Applicable Building Type(s)

Policy Requirement Level

Mandatory

Policy Sequence

Governance

Development Authority: Ministry of the Environment

Implementation Authority: Ministry of the Environment

Verification Authority: Ministry of the Environment

Enforcement Authority: Municipal building inspection

Prescriptive Compliance path

Energy Requirements:

Insulation

U-Values (W/m2.K)

Walls

Floor

Roof

Building elements of warm and cooled cold spaces

0.17

0.09

0.09

Building elements of semi-warm spaces

0.26

0.14

 

 

Windows

U-Values (W/m2.K)

Windows

Building elements of warm and cooled cold spaces

1

Building elements of semi-warm spaces

1.4

 

Total window area should not exceed 50% of total area of external walls

Air Leakage

4 m3/(h.m2) at 50 Pa

Performance Compliance path

Energy Requirements:

Resources

Notes

Climate zones